📈 Build It, Probe It, Measure It
Dual-trace oscilloscope
Linear
CH1 input peak
–
CH2 output peak-to-peak
–
Measured gain
–
Design gain at this frequency
–
Phase shift (fundamental)
–
Input impedance
–
Function generator & circuit
Signal type
10 Hz100 kHz
0.1 V10 V
1 kΩ1 MΩ (E12 values)
1 kΩ1 MΩ (E12 values)
Cycles on screen
Schematic
CH1 probe: input (amber trace)CH2 probe: output (green trace)
How it works
🎯 Technician check
🧪 Guided Labs: Predict, Load, Explain
Write your prediction first, then load the setup and measure. Open "Check your prediction" only after you have a number.
🛠️ What a Junior Technician Needs to Know
| Area | The technician can… | Practice it |
|---|---|---|
| Ideal vs. real op-amp | State the ideal characteristics (infinite gain and input impedance, zero output impedance) and the real limits that matter on the bench: ±Vsat, gain-bandwidth product, slew rate, input offset. | Labs 3, 9, 10 with “Real 741 behavior” on |
| Packages and power | Identify 741 and LM358 pinouts, wire dual and single supplies, and recognize decoupling capacitors and offset-null pins. | Bench / Tinkercad op-amp lab |
| Golden rules and virtual ground | Use “no input current” and “inputs equal under negative feedback” to explain any configuration, and expect about 0 V at the − pin of a working inverting stage. | Inverting and non-inverting modes |
| Gain calculations | Calculate inverting and non-inverting gain from resistor values (including the color code and E12 values) and predict output amplitude and phase. | Labs 1, 2, 4 |
| Configuration recognition | Name a circuit on sight by where the signal enters and what sits in the feedback path: resistor, wire, capacitor, or nothing. | Live schematic panel |
| Comparators | Set a reference, predict output state and duty cycle, and explain chatter and the need for hysteresis. | Labs 5, 6 |
| Integrators and differentiators | Recognize square↔triangle conversions, explain why practical circuits add a bleed resistor or a series input resistor, and find the corner frequency. | Labs 7, 8 |
| Test equipment | Set a function generator; set V/div, time/div and triggering on a scope; measure peak, peak-to-peak, gain and phase. | Scope display and measurement row |
| Troubleshooting | Read the symptom: output stuck at a rail (open feedback), no output (open input or shorted feedback), flattened peaks (clipping), trapezoids (slew), wrong gain (wrong resistor). | Lab 10 and the fault menu |
| Documentation and safety | Pull key specs from a datasheet, handle ICs with ESD precautions, and record measured against expected values. | Bench / lab report |